EnergiaOn products

No matter when and where EnergiaOn is always here for your stable power services

End Suction Centrifugal Pump
End Suction Centrifugal Pump
The direction of rotation The rotation of the pump rotor is clockwise looking from the motor to the pump.

Applications
- Water supply and transfer in municipal and industrial applications.
- Water treatment plants.
- Air-conditioning systems.
- Circulation in cooling and heating systems.
- Irrigation and sprinkler pumping stations.

Product Standard: DIN24255, BS EN733 and ISO9908

General description
SXA series single stage end-suction centrifugal pumps is based on new technology, the pump is successfully design based on long-term technology accumulation and on the experience of domestic and overseas advanced technology.
The casing is end suction and radial discharge design. Its discharge centerline and shaft are in the same vertical plane. The casing is directly fixed on the base-plate.
The pump is back-pull-out design, which allows disassembling the casing cover and rotary components without removing the pipe. The mounting frame is supplied with two ball bearings, lubricate by grease or engine oil.

The suction and discharge flange, the casing and pump foot are all cast to a whole.

The pump comply with DIN24255 and BS EN733 standard, they have high interchangeability.

Specifications
- Pump inlet: DN50 – DN300 mm
- Pump outlet: DN32 – DN250 mm
- Capacity Q range: 4.5 m3/h - 1080 m3/h
- Head H range: 10m - 155m

Operation conditions
- Operating speed: 1450rpm or 2900rpm, 1750rpm or 3500rpm
- Max. Viscosity: 1Cp, Normal temperature (24℃)
- Working Temperature Range: -15℃ ~ 105℃
- Max. Allowable Suction Pressure (MASP): PN0.6MPa
- Max. Allowable Working Pressure (MAWP): PN1.0MPa or PN1.6MPa

The direction of rotation
The rotation of the pump rotor is clockwise looking from the motor to the pump.

The driving type
The motor driver the pump through the Flexible Coupling directly.

Operating limits
operating range : 0.5 to 1.2 x QOpt
- Qopt ----- Pump operating point
Pressure Limits
Standard hydrostatic test pressure
The standard test pressure is calculated as follows:
1.2 x (HQ=0+ HInlet) or 1.5 x (HQ=Qopt+ HInlet) , The higher value is to be used
- HQ=0 ----- Head at close the valve
- HInlet ----- Pump max. inlet pressure
- Qopt ----- Pump operating point

Applications
- Water supply and transfer in municipal and industrial applications.
- Water treatment plants.
- Air-conditioning systems.
- Circulation in cooling and heating systems.
- Irrigation and sprinkler pumping stations.